Answers · from Chapter 57: Thermoelectrics & Heat Cascades

How does a thermoelectric generator work?

How does a thermoelectric generator work?

A thermoelectric generator is a heat engine with no moving parts. Heat flowing from a hot face to a cold face through pairs of semiconductor legs produces a voltage by the Seebeck effect. It converts only a few percent of that heat; spacecraft units convert roughly 5 to 7.5 percent.

Evidence rating: Proven. Claim rated: Flight thermoelectric generators convert roughly 5 to 7.5 percent of the heat crossing their couples. How the ratings work.

What makes the voltage?

In 1821 Thomas Johann Seebeck found that a circuit made of two different conductors produces a voltage when its two junctions sit at different temperatures. Thirteen years later J. Peltier found the reverse: sending a current across a junction warms or chills it. William Thomson, later Lord Kelvin, tied the two effects together in 1855, showing a thermocouple to be a form of heat engine that can make electricity from heat or work as a refrigerator.

A thermoelectric generator puts that effect to work. Couples of n-type and p-type semiconductor legs sit between a hot face and a cold face, and the heat flowing through them drives a current. The flat module Chapter 57 opens with is 40 millimeters square, faced with graphite, with two wires and nothing that moves.

Why is the efficiency so low?

Two losses ride along with the useful effect: resistive (Joule) heating inside the legs, and heat leaking straight through them by conduction. In 1911 Altenkirch listed three things a good couple must have: a strong Seebeck coefficient, electrical conductivity that is high and thermal conductivity that is low. No material of his day offered all three. Together they make up a figure of merit, ZT. The book works an example between 300 °C and 30 °C, where the Carnot limit is 47.1 percent: a couple with a device ZT of 1 could reach 10.0 percent, and one with a ZT of 2 could reach 15.3 percent. In Goldsmid's treatment, a couple loaded for maximum power can never exceed half the Carnot limit, even if no heat leaked through it by conduction.

How much does a real generator convert?

Less again. One maker rates its bismuth telluride module at 9.8 watts from about 188 watts of heat at those temperatures, about 5.2 percent on the book's conversion, though the sheet's own chart reads near 6 percent; it is a module rating rather than a measured system. Heat must also cross into the hot face and out of the cold one, and the low-voltage DC output varies with temperature, so a maximum-power-point tracker takes a share. A 2008 DOE study put thermoelectric systems in use at 2 to 5 percent.

Spacecraft generators are the best-documented case. NASA's Lee Mason puts the Multi-Mission RTG at about 6.5 percent of the heat crossing its couples and 5.5 percent of its fuel heat, and the older silicon-germanium GPHS-RTG at about 7.5 percent. The book rates the 5 to 7.5 percent range Proven.

Where does it make sense?

Mostly on heat that is being thrown away anyway. A generator converting 5 percent passes the other 95 percent on, so it suits jobs where a few watts with no moving parts matter more than efficiency.

What Chapter 57 covers

Chapter 57, Thermoelectrics & Heat Cascades, covers the Seebeck and Peltier effects, the four levels at which efficiency is quoted, radioisotope generators, heat cascades from engines to heat pumps, and a safety box on telluride and lead dusts, hot silicone oil and radioisotope sources.

Sources

Read more in Chapter 57: Thermoelectrics & Heat Cascades, part of Volume II: System Anatomies. All answers · Formats and prices