Does a COP above 1 mean a device produces free energy?

Does a COP above 1 mean a device produces free energy?

A COP above 1 does not mean free energy: a coefficient of performance (COP) divides useful heat by electrical input alone, so a heat pump that also draws heat from the air or ground routinely scores above 1; geothermal units rate 3.6 to 4.8. Over-unity would mean output above every input counted at the boundary. The book rates this Proven.

Evidence rating: Proven. Claim rated: A coefficient of performance above 1 is ordinary and implies no output beyond total input. How the ratings work.

What does COP measure?

A coefficient of performance is the useful heat a unit delivers divided by the electricity it draws. A heat pump does not make its heat from electricity; it moves heat from outdoor air or the ground into a building. That moved heat is a real input, but no electricity meter records it, so the ratio of output to metered input comes out well above 1.

How high can it go?

US Department of Energy purchasing guidance lists geothermal heat pumps at a heating COP of 3.6, the ENERGY STAR level, rising to 4.8 for the top models, all tested under ISO 13256-1. Thermodynamics caps the figure. A perfect heat pump lifting heat from 0 °C ground to deliver it at 35 °C would score about 8.8.

Then what would over-unity mean?

Output greater than all inputs, each counted where it crosses a line drawn around the device: electrical drive, shaft power, field-coil supply, heat from the surroundings, and energy drawn down from a battery or capacitor. A machine can return well over its electrical input while the full energy books still balance. The misreading is to compare output with the electricity alone. The book rates "A coefficient of performance above 1 is ordinary and implies no output beyond total input" as Proven.

How should such a claim be tested?

Chapter 5 sets out the method. Meter every input at the boundary, measure stored energy at the start and end of the run, and compute power from simultaneous voltage and current samples rather than from two separate meter readings. For heat, calibrate the calorimeter in place with a known heater. Report the result with its uncertainty. A device measured at 1,000 W in and 1,050 W out, with standard uncertainties of 2 and 3 percent, gives a ratio of 0.97 to 1.13 at a coverage factor of 2 (about 95 percent confidence), which neither shows excess nor rules it out.

What Chapter 5 covers

Chapter 5 of The Forbidden Current covers the n-ray episode of 1904, energy boundaries, power measurement with true-RMS meters and analyzers, calorimetry, thrust balances, blinding, pre-registration and replication, and how the book assigns each evidence status.

Sources

  • ISO 13256-1, rating method for geothermal heat pumps
  • US Department of Energy, purchasing guidance for geothermal heat pumps
  • B. N. Taylor and C. E. Kuyatt, NIST Technical Note 1297 (1994)

Read more in Chapter 5: How to Test an Extraordinary Claim, part of Volume I: Preserving Knowledge. All answers · Formats and prices