How to Test an Extraordinary Claim
Energy boundaries, pulsed-power measurement, calorimetry, thrust balances, blinding and uncertainty, and how the book assigns a status.
A guide to the chapter, written for this site. It describes the chapter; it is not an extract from it.
What the chapter covers
Chapter 5 is the method chapter: how to test a claim that a machine breaks conservation of energy or momentum, and how those tests become the status in each evidence box. It opens in Nancy in 1904, where Robert W. Wood watched René Blondlot demonstrate the n-rays and found the effect lived in the observer's eye. Richard Feynman's 1974 Caltech address and Irving Langmuir's 1953 talk on "pathological science" supply the working rules. The chapter then draws a boundary around a device and meters everything that crosses it, using the N-machine tests of DePalma (1980) and Kincheloe (1986) as the example. A long section shows why pulsed power must be computed from simultaneous voltage and current samples, not from two RMS readings, and how average-responding meters and timing skew mislead. Heat claims go to flow and isoperibolic calorimetry, with the 1989 Department of Energy review of cold-fusion cells. Force claims go to thrust balances, with the EmDrive tests at NASA Eagleworks (2016) and TU Dresden (2021). Blinding, pre-registration, the OPERA neutrino timing of 2011 and replication follow, then a nine-point checklist and measurement uncertainty after the GUM and NIST Technical Note 1297. The last section defines each of the five statuses and the two types.
Claims the chapter rates
Each claim gets one rating on the book's scale. How the ratings work.
| Claim | Rating | Kind |
|---|---|---|
| Real power in a pulsed circuit is the average of simultaneously sampled v × i, not the product of separate RMS readings | Proven | empirical |
| A coefficient of performance above 1 is ordinary and implies no output beyond total input | Proven | empirical |
| A well-run null result rules out effects larger than its sensitivity, under the conditions tested, and nothing smaller | Proven | empirical |
Key numbers
- 10 A pulse, 10% duty: mean / RMS / average-responding meter, DC (AC) coupled
- 1.0 A / 3.16 A (3.00 A) / 1.11 A (2.0 A) (computed in the chapter)
- Real-power error from 1 degree voltage-current skew (sine, at the fundamental)
- 3.0% at PF 0.5; 17% at PF 0.1 (computed in the chapter)
- Thermoneutral voltage, electrolysis
- 1.48 V (H2O); 1.527 V (D2O) (DOE ERAB 1989)
- Photon-thrust benchmark
- 3.3 nN/W (Tajmar et al. 2021)
- OPERA neutrino timing, 2011 to 2012
- 60.7 ns early, corrected to 6.5 ns (arXiv:1109.4897)
Questions this chapter answers
How do you measure power in a pulsed circuit correctly?
Correct pulsed-power measurement samples voltage and current at the same instants, multiplies each pair, and averages the products over whole cycles. Multiplying a separate RMS voltage reading by a separate RMS current reading gives apparent power, which can far exceed real power when the waveforms are spiky or out of phase. Probe timing skew matters too: 1 degree costs 17% at a power factor of 0.1.
Why can a cheap meter misread a pulsed current?
Many meters average the rectified signal and scale it for a sine wave. On a 10 A pulse at 10% duty the true average is 1.0 A and the RMS value is 3.16 A, yet a DC-coupled meter of that type shows about 1.11 A and an AC-coupled one 2.0 A. True-RMS meters are limited by crest factor and bandwidth; a power analyzer multiplies simultaneous voltage and current samples.
What does a null result prove?
A well-run null result rules out any effect larger than the test could detect, under the conditions actually used, and says nothing about smaller effects. The book rates that principle Proven. The 2021 Dresden EmDrive balance, for example, found no thrust above its noise and put any anomalous thrust at or below roughly the photon benchmark of 3.3 nN/W, which does not exclude a weaker effect.
What counts as an independent replication?
A second group, separate from the first, using its own apparatus and instruments, obtains the same result under matching conditions. The original team repeating its work on the original rig shows only repeatability, since the rig's own systematic errors come along. A failed replication persuades most when the first team accepts its conditions as fair.
How does the book decide an evidence status?
Proven needs independent replication with different apparatus and engineering use. Plausible fits established physics with thin direct evidence. Disputed has credible evidence pointing both ways. Untested has no credible measurement. Examined, not replicated has at least one credible measurement that no independent group has reproduced. A separate type line marks each claim empirical or interpretive.
Selected sources
- R. W. Wood, "The n-Rays," Nature 70 (1904), pp. 530-531
- I. Langmuir, "Pathological Science," Physics Today (1989), from a 1953 colloquium
- R. P. Feynman, Caltech commencement address (1974)
- US Department of Energy, Energy Research Advisory Board, Cold Fusion Research (1989)
- M. Tajmar et al., EmDrive thrust-balance tests, TU Dresden (2021)
- OPERA Collaboration, neutrino velocity measurement, arXiv:1109.4897
- B. N. Taylor and C. E. Kuyatt, NIST Technical Note 1297 (1994)
- Does a COP above 1 mean a device produces free energy?
- Glossary: Calorimetry
- Glossary: Coefficient of performance (COP)
- Glossary: Evidence status
- Glossary: True RMS (root mean square)