Answers · from Chapter 60: Wind & Water

How does a hydraulic ram pump work?

How does a hydraulic ram pump work?

Water speeds up down a rigid drive pipe until its flow slams a waste valve shut. The sudden stop raises the pressure, water hammer, which pushes a small share of the water through a delivery valve and up the delivery pipe, then the cycle repeats.

Evidence rating: Plausible. Claim rated: A hydraulic ram can transfer more than half the driving flow's energy to the delivered water. How the ratings work.

The cycle

A ram pump needs no fuel or electricity; the falling water drives it. Chapter 60 follows Practical Action's technical brief, which credits the Montgolfier brothers of France with the first self-acting ram, in 1796 (the brief spells the name Mongolfier).

Water from a source above the pump runs down a rigid drive pipe and escapes through a waste valve, which the brief calls the impulse valve. As the flow gains speed, pressure under that valve overcomes its weight and begins to close it. Pressure then climbs fast and the valve snaps shut. The moving column of water is stopped almost at once, and that surge, known as water hammer, drives some water past a one-way delivery valve into an air chamber and on up the delivery pipe. The pressure wave rebounds, the waste valve falls open again, and the process repeats 30 to 100 times a minute by the brief's figure. The trapped air cushions the pulses so the delivered flow is steady.

How much water it delivers

Efficiency is the delivered flow times its lift, divided by the drive flow times its fall: q times h over Q times H. Energy sets the trade. Raise the lift relative to the fall and less of the water reaches the delivery point. Practical Action says more than half the driving flow's energy can reach the delivered water. The chapter rates that Plausible: the brief's table is labeled estimated performance, not a measured test, with neither the ram model nor the test conditions stated.

The book's worked example. The brief's Table 1 lists a ram with a 4-inch drive and 2-inch delivery at a head ratio of 10, taking 9.7 L/s of drive flow for 51 m³ a day delivered. Taking the ratio to mean lift divided by fall (the book's reading) and an efficiency of 0.6 yields 0.58 L/s, which is 50.3 m³ a day (the book's arithmetic), near the tabled value. The row as a whole implies efficiencies of 59 to 61 percent (calculated). With a tenfold ratio, roughly 94 percent of the drive water (calculated) continues downstream rather than up the delivery pipe, so a ram suits a site with water to spare.

What the brief says about the pipe and the pump

The brief sets the drive pipe by proportion: its length should be between three and seven times the supply head, and no less than 100 diameters. It must be rigid and straight, since surges at a bend work the pipe loose. Cast rams, it says, can run for 50 years or more, while welded ones last around ten. The chapter's safety box treats the shock loads as a real hazard: Practical Action warns that if the air chamber fills completely with water, the hammer can crack the body, the drive pipe or the chamber itself.

What Chapter 60 covers

Chapter 60 covers small wind and the Betz-Joukowsky limit, measured capacity factors, axial-flux alternators, measuring a micro-hydro site, choosing a runner and the hydraulic ram.

Sources

Read more in Chapter 60: Wind & Water, part of Volume III: Off-Grid Solutions. All answers · Formats and prices