Volume III · Part XIV: The Homestead Microgrid · Chapter 60
Wind & Water
Small wind and the Betz-Joukowsky limit, measured capacity factors, axial-flux alternators, micro-hydro sites and the hydraulic ram.
A guide to the chapter, written for this site. It describes the chapter; it is not an extract from it.
What the chapter covers
This chapter treats wind and falling water as two measurable resources with different physics. Power in wind rises with the cube of speed, so the chapter works power density at 3, 5 and 10 m/s, sets the Betz-Joukowsky ceiling of 16/27 against the 0.25 to 0.45 DOE gives for real machines and the 25 to 35 percent Hugh Piggott gives for homebuilt blades, and rates that rotor range Plausible. It reads the limit's history through Okulov and van Kuik. Siting follows, with DOE's tower rule, the Griggs-Putnam vegetation index and PNNL's 2024 measured average net capacity factor of 13 percent for 100 small wind projects. Axial-flux permanent-magnet alternators and washer-motor generators are matched to slow rotors through pole count and frequency. Water power rises only linearly with head and flow; the 1983 DOE/INEL micro-hydro handbook supplies methods for measuring head and flow, the flow duration curve, system efficiency and handbook ratings for Pelton, Turgo and crossflow runners. The hydraulic ram closes the chapter: how its valves and water hammer lift water with no outside power, Practical Action's efficiency claim, rated Plausible, and a worked delivery example, followed by testing and a safety box.
Claims the chapter rates
Each claim gets one rating on the book's scale. How the ratings work.
| Claim | Rating | Kind |
|---|---|---|
| A real small wind rotor captures at best about 25-45 percent of the power in the wind | Plausible | empirical |
| A hydraulic ram can transfer more than half the driving flow's energy to the delivered water | Plausible | empirical |
Key numbers
- Betz-Joukowsky limit
- 16/27, about 59.3 percent (theory, open stream tube) (Okulov and van Kuik)
- Real-turbine power coefficient
- 0.25 to 0.45 (DOE small wind guide (2007))
- Small wind average net capacity factor, 2023
- 13 percent, up to 28 percent (measured, 100 projects) (PNNL 2024)
- Micro-hydro system efficiency
- 40 to 75 percent (handbook) (DOE/INEL Microhydropower Handbook (1983))
- Ram pump cycle rate
- 30 to 100 cycles a minute (Practical Action, Hydraulic Ram Pumps)
Questions this chapter answers
How much of the wind's power can a rotor capture?
Theory caps an open rotor at 16/27, about 59.3 percent, the Betz-Joukowsky limit. Real machines do less: DOE's guide gives 0.25 to 0.45 and Piggott gives 25 to 35 percent for homebuilt blades, neither backed by a named test series. The chapter rates the 25 to 45 percent range Plausible.
How much energy does a small wind turbine actually produce in a year?
Across 100 small wind projects in 2023, PNNL's 2024 report found net capacity factors averaging 13 percent and reaching as high as 28 percent. At that average a 5 kW turbine yields 5,694 kWh a year, the book's arithmetic. The same model can do very differently at different sites, so measure the wind first.
How does a micro-hydro site compare with a wind site?
Water power grows in proportion to head and flow, not as a cube, and a stream can run around the clock, though its flow varies by season. The book's example of 5 L/s through 30 m of net head at 50 percent efficiency gives 736 W, a planning figure and not a measurement. The INEL handbook puts whole-system efficiency at 40 to 75 percent, below its turbine peak ratings.
How does a hydraulic ram lift water with no motor?
Water accelerates down a rigid drive pipe and out a waste valve until the flow slams that valve shut. That sudden stop, water hammer, sends a small share past the delivery valve, through an air chamber and on up the delivery pipe, at the brief's rate of 30 to 100 times a minute. Practical Action says more than half the driving energy can transfer; the chapter rates that Plausible.
Selected sources
- US Department of Energy, Small Wind Electric Systems, A U.S. Consumer's Guide, DOE/GO-102007-2465 (2007)
- V. L. Okulov and G. A. M. van Kuik, The Betz-Joukowsky limit, author manuscript (Wind Energy 15, 2012)
- H. Piggott, How to Build a Wind Turbine, Axial Flux Alternator Windmill Plans (2003)
- L. Sheridan, K. Kazimierczuk, J. Garbe, D. Preziuso, Distributed Wind Market Report, 2024 Edition, PNNL-36057
- B. Leyland, From washing machine motor to micro hydro generator
- J. D. McKinney, C. C. Warnick et al., Microhydropower Handbook, Vol. 1, IDO-10107, EG&G Idaho for US DOE (1983)
- Practical Action, Hydraulic Ram Pumps (technical brief)
- US OSHA, Wind Energy
Related chapters