Volume II · Part IX: Materials: How the Parts Come to Exist · Chapter 42

Repurposing & Longevity

How heat sets the life of capacitors, batteries, motors and solar modules, and which discarded machines hold sound parts.

A guide to the chapter, written for this site. It describes the chapter; it is not an extract from it.

What the chapter covers

This chapter asks why discarded machines often hold parts with years of service left, and answers with one theme: temperature is the clock. It goes through the parts that age. Aluminum electrolytic capacitors lose electrolyte through their seals, and one maker rates them at 1,000 to 20,000 hours with life doubling for every 10 °C cooler, a maker's rule. Sealed lead-acid batteries in a UPS are consumables with a float life of about five years in Yuasa's manual. Motors fail mostly at the bearings, by the DOE's count, and their insulation ages with heat. Solar modules degrade slowly, with fleet figures given in a rated box. Silicon, solder, tin whiskers and magnets follow. The second half reads donor machines as anatomy, each with a suitability verdict: the claw-pole car alternator, built for high speed and a 14 V battery; Fisher & Paykel's outer-rotor washer motor, slow and brushless; the UPS, sorted into the DOE's three classes; hard-drive magnets; and the RV absorption fridge with its sodium chromate. The microwave oven gets the verdict "none": its high-voltage section is described only to explain why it is not a donor. A safety box draws on the CPSC, EPA, OSHA, FDA and MIT, and a closing section separates consumables from long-life parts.

Claims the chapter rates

Each claim gets one rating on the book's scale. How the ratings work.

ClaimRatingKind
"Solar modules and systems lose about 0.5–0.75 percent of their output a year"Provenempirical

Key numbers

Aluminum electrolytic capacitor, rated life at maximum core temperature
1,000-20,000 h (maker's rating) (Cornell Dubilier (n.d.))
VRLA battery float life
about 5 years at about 20 °C (maker's figure) (Yuasa NP manual (Rev 5/00))
Share of motor failures due to bearings
nearly two-thirds (DOE Motor Tip Sheet)
PV loss per year, 2012 median for modules and systems / 2022 median for systems
0.5 percent a year (2012 review); 0.75 percent a year (2022 fleet) (Jordan and Kurtz (2012); Jordan et al. (2022))
Microwave oven HV section, transformer / doubled
about 2,000 V / about 4,000 V (US Patent 6,153,870 (2000))

Questions this chapter answers

Can you reuse a microwave oven transformer?

The book offers no microwave-transformer reuse: the chapter gives the oven a suitability of none. Its transformer feeds a voltage doubler, and the magnetron runs at about 4,000 V. The CPSC counts an annual average of two repair electrocutions and warns of shock after unplugging. Capacitors from before 2 July 1979, or undated, are presumed to hold 500 ppm of PCBs or more unless marked "No PCBs" or tested.

How long do electrolytic capacitors last?

Cornell Dubilier rates electrolytic capacitors for 1,000 to 20,000 hours when run at their maximum core temperature, which it equates to six weeks through 2.28 years. Its model, a maker's rule for moderate temperatures, doubles that for every 10 °C cooler, so a part running cool can outlast its product. Unpowered storage also ages them; the maker allows about five years at 5 to 40 °C.

Why does a UPS stop working?

A UPS usually stops working because its sealed lead-acid battery has reached the end of its life. Yuasa puts float life near five years with the battery at about 20 °C. The inverter behind it is often still sound, with its life set by capacitors and heat. For battery and inverter installations, check the code in force where you are.

Is a car alternator a good generator for wind or water power?

The chapter judges a car alternator robust and cheap but poorly matched. Its design suits a fast shaft charging a 14 V battery; it gives little at low speed, and its field draws power. One 12 V, 100 A unit, run at maximum field current, reached 53 percent efficiency idling, falling to about 42 percent at 6,000 rpm. For generator installations, check the code in force where you are.

Selected sources

  • Cornell Dubilier Electronics, Aluminum Electrolytic Capacitor Application Guide (n.d.)
  • Yuasa Inc., NP Series Valve Regulated Lead Acid Battery Application Manual (Rev 5/00)
  • US DOE Advanced Manufacturing Office, Extend the Operating Life of Your Motor, Motor Systems Tip Sheet
  • US DOE AMO, Improving Motor and Drive System Performance, A Sourcebook for Industry (2014)
  • D. C. Jordan and S. R. Kurtz, Photovoltaic Degradation Rates, An Analytical Review, Prog. Photovolt. (2012)
  • D. C. Jordan et al., Photovoltaic fleet degradation insights, Prog. Photovolt. (2022)
  • G. Badran, V. K. Lazarov, M. Dhimish, Extending Photovoltaic Module Lifetime Through Targeted Repair of Short-Circuited Bypass Diodes, Solar 6 (2026)
  • US Department of Defense, MIL-HDBK-217F Notice 2, Reliability Prediction of Electronic Equipment (1995)
  • R. Ivankovic et al., Power Electronic Solutions to Improve the Performance of Lundell Automotive Alternators (2012)
  • US Patent 6,153,870 (2000), AC/DC microwave oven
  • US CPSC, Electrocution Hazard with Do-It-Yourself Repairs of Microwave Ovens, Publication 5061 (2012)
  • 40 CFR 761.2(a)(4), PCB concentration assumptions for capacitors

More on this chapter

Related chapters

This chapter is in Volume II: System Anatomies. Drafted and twice audited; chapter text final. Formats and prices · All chapters