Volume II · Part IX: Materials: How the Parts Come to Exist · Chapter 39
Insulators & Dielectrics
The Leyden jar, Faraday's measurements, permittivity, dielectric strength, loss, partial discharge, PCBs and thermal aging.
A guide to the chapter, written for this site. It describes the chapter; it is not an extract from it.
What the chapter covers
This chapter argues that insulation is not passive: besides blocking current, a dielectric stores energy, wastes part of it and breaks down in characteristic ways. It opens with Kleist's charged phial of 1745 and the Leyden jar, then Faraday's 1837 spherical condensers, which gave the first figures for what he named specific inductive capacity, now relative permittivity. Three properties describe a practical material: permittivity, dielectric strength and loss, and Peek's 1915 measurements show they do not track one another. The failure section covers puncture through the bulk, flashover and tracking along surfaces, and corona and partial discharge, with the rule that a gas or liquid can recover after a local breakdown while a solid keeps the damage. Materials follow: glass, mica, porcelain, oil and paper, shellac and the metallized film capacitor that clears its own faults. PCB askarels, and the silicone fluids that took over part of their indoor market, get their own section, with the US 500 and 50 ppm thresholds. The last section treats thermal aging, from Montsinger and Dakin to motor insulation classes. Two rated boxes, both Plausible, cover the halving-per-degree rule and partial discharge, and a safety box covers stored charge, PCBs and asbestos.
Claims the chapter rates
Each claim gets one rating on the book's scale. How the ratings work.
| Claim | Rating | Kind |
|---|---|---|
| "Insulation life halves for every 8-10 °C rise in temperature" | Plausible | empirical |
| Partial discharge causes most long-term failures of solid high-voltage insulation | Plausible | empirical |
Key numbers
- Air breakdown, sea level, 25 °C
- about 30 kV/cm (Peek (1915))
- Single-layer varnished cloth puncture, instant vs after 20 minutes
- 52.5 vs 30.2 kV/mm (Peek (1915))
- Motor insulation class limits A/B/F/H (40 °C ambient, SF 1.0)
- about 100/120/145/165 °C (US DOE (2014))
- US PCB manufacture
- 1929-1979 (US EPA, Learn about PCBs)
- PCB Transformer / PCB-Contaminated equipment (US)
- 500 ppm or more / 50 to under 500 ppm (40 CFR 761.3)
Questions this chapter answers
What is dielectric strength?
Dielectric strength is the electric field at which an insulating material breaks down, quoted in kilovolts per centimeter or millimeter. Peek's figure for air is about 30 kV/cm, measured at sea-level pressure and 25 °C. A strength figure only holds for a stated thickness, test time and temperature: one layer of varnished cloth fell from 52.5 to 30.2 kV/mm after twenty minutes.
Does insulation life really halve for every 10 °C rise?
Insulation life halves per 10 °C only roughly: the chapter rates the halving rule Plausible. Aging is a chemical reaction following the Arrhenius law, and government manuals print the rule with steps of 8 to 10 °C. The step depends on the material, holds only while one reaction dominates, and ignores moisture, vibration and electrical stress. Endurance tests give the figure for a specific system.
What is partial discharge in insulation?
Partial discharge is a breakdown that does not bridge the whole gap. A gas void inside a solid concentrates the field, and discharges in it erode the walls and can grow branching treeing channels over years. The chapter rates Plausible the claim that it causes most long-term failures of solid high-voltage insulation; no failure share was found.
Why can old transformers and capacitors contain PCBs?
PCB fluid may be inside equipment built before 2 July 1979, because PCBs were adopted as fire-resistant insulating fluids that do not burn, stay stable and insulate well. US manufacture ran from 1929 until the 1979 ban, but older equipment stayed in service. Federal rules set what untested older or undated equipment is presumed to hold. Testing and disposal are regulated under 40 CFR 761.
Selected sources
- J. Priestley, The History and Present State of Electricity, 3rd ed. (1775)
- M. Faraday, Experimental Researches in Electricity, Eleventh Series (1837; reprinted 1839)
- F. W. Peek Jr., Dielectric Phenomena in High Voltage Engineering (1915)
- D. Tommasini, Dielectric insulation and high-voltage issues, CERN Accelerator School, arXiv:1104.0802 (2011)
- US Bureau of Reclamation, FIST 3-30, Transformer Maintenance (2000)
- US Bureau of Reclamation, Transformers: Basics, Maintenance, and Diagnostics (2005)
- US Patent 9,384,895 B2, Polytetrafluoroethylene film capacitor (2016)
- US EPA, Learn about Polychlorinated Biphenyls
- 40 CFR 761.2 and 761.3, PCB definitions and presumptions
- US DOE, Premium Efficiency Motor Selection and Application Guide (2014)
- US EPA, Chrysotile Asbestos final rule, 89 Fed. Reg. 21970 (2024)
- US DOE, Electrical Safety, DOE-HDBK-1092-2013
Related chapters
This chapter is in Volume II: System Anatomies. Drafted and twice audited; chapter text final. Formats and prices · All chapters