Volume II · Part X: Machines · Chapter 46

Power Electronics

Switching instead of burning, rectifiers and the SCR, buck and boost, PWM and MPPT controllers, inverters and their light-load losses.

A guide to the chapter, written for this site. It describes the chapter; it is not an extract from it.

What the chapter covers

Chapter 46 opens with a short 1925 paper in the General Electric Review in which D. C. Prince named the inverter as a rectifier run in reverse, turning direct current into alternating with no rotating machine. Its theme is that a converter should switch rather than burn. A series regulator wastes the voltage it drops, so its efficiency can be no better than output over input, while an ideal switch dissipates nothing and its duty cycle sets the average the load sees. The chapter walks from half-wave, full-wave and bridge rectifiers with their ripple and smoothing capacitors to the thyratron, the 1957 silicon controlled rectifier, the TRIAC and gate turn-off thyristors that grew from it, and the MOSFET and IGBT that joined them. Buck and boost converters follow, with worked figures between 12 V and 48 V. It then explains charge controllers, contrasting the simple PWM switch with MPPT tracking using a maker's own worked case, and inverters: the H-bridge, square, modified-sine and true-sine output, surge and input current, and the difference between grid-following and grid-forming units. Two evidence boxes close the chapter, one on how far efficiency falls at light load and one on whether inverters are the weak point of large solar plants, followed by a safety box covering charge left in capacitors, battery short-circuit current, live arrays, DC arcs and backfeed.

Claims the chapter rates

Each claim gets one rating on the book's scale. How the ratings work.

ClaimRatingKind
"An inverter's efficiency falls well below its rated peak at light load"Provenempirical
"Inverters are the weak link in commercial and utility solar plants"Plausibleempirical

Key numbers

Ripple frequency on a 60 Hz supply
60 Hz half-wave; 120 Hz full-wave (NEETS Mod 7, pp. 4-10, 4-14)
Rated efficiency of grid-tied PV inverters (2007 database)
91 to 96%, mostly maker figures (Sandia 2007, p. 17 and appendix)
Stand-alone inverter surge, 2001 ("frequently")
4 to 6 times rating, for seconds (Sandia 2001 (Wiles, SAND2001-0674))
Fronius IG3000 at a tenth of rated DC input
about 88% (Sandia 2007 model, computed from CEC data)
PWM vs MPPT, 100 W module at 25 degrees C (maker's worked case)
81 W vs 100 W (Victron Energy (2020))

Questions this chapter answers

What does an inverter do?

An inverter turns direct current, from a battery or a solar array, into alternating current. Four transistor switches in an H-bridge close in diagonal pairs, so current runs one way through the load and then the other. Rapid switching, with each pulse width shaped to track a sine, plus an output filter, gives a true sine wave. Check the code in force where you are.

Why is a switching converter more efficient than a linear regulator?

A linear regulator burns the voltage it drops. In the book's example, taking 12 V at 10 A from a 48 V bank wastes 360 W to deliver 120 W, for 25 percent efficiency. A buck converter chops the input at a duty cycle of 0.25 and smooths it, so the bank supplies only 2.5 A and, ideally, nothing turns into heat.

What is the difference between a PWM and an MPPT charge controller?

A PWM controller is a switch that ties the array straight to the battery, which drags the array down to battery voltage. An MPPT controller adds a buck converter and a tracking routine that keeps the array at its most productive voltage and turns the surplus into extra current. In Victron's own worked case PWM delivered 81 W against 100 W at 25 degrees C.

Why do larger battery systems run at 24 or 48 volts?

Power is voltage times current, so a low bank voltage means heavy current. In the example from Sandia's 2001 guide, a 2,500 W inverter on a 24 V bank, about 85 percent efficient at 22 V, draws roughly 134 A, and the guide's reading of the 1999 code wants conductors sized for about 167 A. Check the code in force where you are.

What is a grid-forming inverter?

Most grid-connected inverters are grid-following: a phase-locked loop locks them to the voltage the utility sets, and they inject current in step. A grid-forming inverter fixes voltage and frequency itself, as a generator does. NREL's 2020 roadmap discusses the shift, and an off-grid battery inverter must be grid-forming. Check the code in force where you are.

Selected sources

More on this chapter

Related chapters

This chapter is in Volume II: System Anatomies. Drafted and twice audited; chapter text final. Formats and prices · All chapters