Answers · from Chapter 46: Power Electronics

What does a solar charge controller do?

What does a solar charge controller do?

A solar charge controller sits between a solar array and a battery bank, ends charging once the battery is full and usually cuts off the load before the battery runs too low. A PWM type is a switch; an MPPT type is a DC-to-DC converter that keeps the array at its most productive voltage.

The basic job

A solar system with a battery bank puts a controller between the array and the bank, and Chapter 46 gives it two duties: stop charging when the battery is full, and in most designs disconnect the load before the battery falls too far. How it handles the array's voltage while charging is what separates the two common types.

The PWM controller

The simpler type, named for pulse-width modulation, is in effect one switch. It joins the array directly to the battery, switching on and off to keep the charging voltage at its set point. While the switch is closed, the array and the battery share one voltage, so the array is pulled down to whatever the battery sits at.

That is where energy goes missing. A solar module delivers its greatest power at one particular voltage, and for a module meant for a 12 V system that voltage is usually well above the battery's.

The MPPT controller

A maximum-power-point-tracking controller adds a buck converter, the step-down circuit the chapter explains earlier, in which a fast switch, an inductor and a capacitor turn one DC voltage into a lower one with little loss. Because power in equals power out in the ideal case, dropping the voltage raises the current. The tracking part is a search routine that keeps adjusting until the array works at its best voltage. The controller then hands the battery a lower voltage and a larger current.

How much difference it makes

The chapter uses a controller maker's own worked case from Victron Energy, and labels it that way. Take a 100 W module that peaks at 18 V and 5.56 A. Wired to a 12 V battery by a PWM controller, it is held near 13.5 V and supplies about 6 A, or 81 W. An MPPT controller harvests the full 100 W at a cell temperature of 25 degrees C, so PWM gives 19 percent less. At 75 degrees C the module's best voltage falls near the battery's, and in the maker's reckoning the MPPT advantage disappears. That is the maker's example for one module at two cell temperatures, 19 percent at 25 degrees C and nil at 75 degrees C, not a rule for every array.

What a controller is not

The chapter's safety box adds that charge controllers are not overcurrent protection, that an array in daylight is always live, and that a DC circuit broken under load holds its arc much longer than an AC one. Check the code in force where you are.

Where to read more

Chapter 46 covers the buck converter, PWM switching and inverters; Chapter 59 covers the array in practice.

Sources

Read more in Chapter 46: Power Electronics, part of Volume II: System Anatomies. All answers · Formats and prices