Answers · from Chapter 46: Power Electronics
What does an inverter do?
What does an inverter do?
An inverter turns direct current from a battery or solar array into alternating current. Transistor switches reverse the current through the load many times a second, and pulse-width modulation plus a filter shapes the result into a sine wave. The book rates the claim that efficiency drops well below peak at light load Proven.
A rectifier run backward
In 1925 D. C. Prince, writing in the General Electric Review, described the inverter as the inverse of a rectifier: a way to make alternating current from direct current without a rotating machine. His switches were vacuum tubes. Chapter 46 treats the two as one idea working in opposite directions, a bridge on the way in, a bridge on the way out, and a DC link between them.
The H-bridge
A modern inverter uses four transistor switches arranged as an H. Close one diagonal pair and current flows through the load in one direction; close the other pair and it flows back. Swap the pairs in turn and the output alternates. Capacitors on the DC side keep the input voltage steady and supply the sharp pulses of current the switches demand, and a gate driver converts the controller's logic into the voltages that actually open and close the transistors.
Square, modified sine, true sine
Switching each pair once per cycle gives a square wave. Holding the output at zero for part of each half-cycle gives the "modified sine" sold in cheaper units. A true sine needs pulse-width modulation, in which the bridge switches many thousands of times each second, the width of each pulse tracks a sine, and an output filter smooths away everything but the intended wave.
Surge and input current
Motors draw several times their running current to start, so surge rating matters. Sandia's 2001 guide reported that stand-alone inverters of the day often managed four to six times their rating for a few seconds. Input current matters too, because power is conserved: in the guide's example, a 2,500 W inverter on a 24 V bank, about 85 percent efficient with the bank sagging to 22 V, pulls roughly 134 A at full output. Heavy current at low voltage is why bigger systems use 24 or 48 V banks.
Efficiency at light load
Datasheets usually quote peak efficiency. The controls inside an inverter cost a roughly fixed amount of power, which is trivial at full output and large at a trickle. Sandia's 2007 model, fitted to lab data for one 2,700 W grid-tied unit, gives about 94 percent at rated input, 88 percent at a tenth (close to the lowest level tested) and 79 percent at a twentieth (under that range). The chapter's evidence box rates the light-load drop Proven; what it costs a household depends on the unit and on its hours at low load.
Grid-following and grid-forming
Most grid-tied inverters lock onto the voltage the utility already sets and feed current in step. A grid-forming unit sets its own voltage and frequency, as an off-grid battery inverter must. Tied to building wiring, an inverter can energize the utility line in an outage. The chapter names IEEE 1547 as the interconnection standard covering anti-islanding and UL 1741 as the product-safety standard for grid-interactive inverters; grid-following units are designed to stop when grid voltage disappears. Check the code in force where you are.
Where to read more
Chapter 46 also covers rectifiers, the SCR, buck and boost converters and charge controllers.
Sources
- D. C. Prince, The Inverter, General Electric Review 28, no. 10 (Oct. 1925)
- J. Wiles, Photovoltaic Power Systems and the National Electrical Code, Suggested Practices, SAND2001-0674 (Sandia, 2001)
- D. L. King et al., Performance Model for Grid-Connected Photovoltaic Inverters, SAND2007-5036 (Sandia, 2007)
- Y. Lin et al., Research Roadmap on Grid-Forming Inverters, NREL/TP-5D00-73476 (2020)
Read more in Chapter 46: Power Electronics, part of Volume II: System Anatomies. All answers · Formats and prices