Volume II · Part X: Machines · Chapter 43
The Rotating Field & the Induction Family
How phased currents turn a field, slip and synchronous speed, cage rotors, single-phase starting and the induction generator.
A guide to the chapter, written for this site. It describes the chapter; it is not an extract from it.
What the chapter covers
Chapter 43 begins in 1824, when Arago reported that a copper plate set spinning will pull along a magnet hung over it, and asks how engineers learned to make a magnetic field turn with no magnet moving. Walter Baily managed it in jerks in 1879 with switched electromagnets. Galileo Ferraris and Nikola Tesla each managed it smoothly with alternating currents out of step, and the chapter compares what each man actually described, alongside a later German patent for the cage rotor itself. It then explains the mechanism: a pair of coils set square to each other and driven a quarter-cycle out of step, or three coils on three-phase, give a field of steady strength that turns at synchronous speed. The rotor always lags behind, and that lag, the slip, also fixes the share of power lost as heat in the rotor. Cage and wound rotors follow, then the tricks that let a single-phase motor start, and the same machine driven faster than its field so that it generates. An evidence box covers the overvoltage an induction generator can reach when it is left with capacitors and a light load, using a 2011 event on a Norwegian line. The chapter closes with efficiency classes, US motor rules and the variable-frequency drive.
Claims the chapter rates
Each claim gets one rating on the book's scale. How the ratings work.
| Claim | Rating | Kind |
|---|---|---|
| Ferraris discovered the rotating field; Tesla invented the induction motor | Disputed | interpretive |
| An induction generator left with capacitors and little load can drive itself to dangerous overvoltage | Proven | empirical |
Key numbers
- Synchronous speed, four-pole machine
- 1,800 rpm on 60 Hz; 1,500 rpm on 50 Hz (standard relation, 120 f / p; Lawrence 1916)
- NEMA Design B slip
- 1-5% (DOE 2014, Table 6-3)
- NEMA Design B starting current
- 600-700% of rated (DOE 2014, Table 6-3)
- EISA minimum full-load efficiency (NEMA Premium, 4-pole enclosed)
- 85.5% (1 hp) to 96.2% (200 hp) (DOE 2014, Table 2-1)
- Seljord 2011, simulated peak after islanding
- about 50 kV within 0.4 s, on a 22 kV rms system (Edvardsen and Winkler 2014)
Questions this chapter answers
How does an induction motor make its magnetic field turn?
Two coils set at right angles carry alternating currents a quarter-cycle apart. As one current falls the other rises, so their combined field keeps one strength while its direction sweeps round evenly. Three coils spaced 120 degrees apart on three-phase supply give the same result more smoothly. The turning field drags the rotor along through the currents it induces there.
Why does an induction motor never quite reach synchronous speed?
A rotor turning exactly with the field would see no change in flux, so it would carry no induced current and get no torque. It therefore always runs a little slower. That lag, measured against synchronous speed, is the slip, and by the energy law Ferraris gave in 1888 the rotor turns that same fraction of the power crossing the air gap into heat.
Why does a single-phase motor need help to start?
One coil on single-phase mains gives a field that pulses rather than turns. It behaves like two fields rotating opposite ways, so a stationary rotor is pulled equally in both directions and only hums. Household motors add a start winding whose current leads the main one, using extra resistance or a capacitor, while the smallest fans rely on a copper shading ring on each pole.
Can an induction motor work as a generator?
An induction motor can work as a generator: driven faster than synchronous speed, its slip turns negative and it pushes power into a line that already sets voltage and frequency. With capacitors across its terminals it can also build up voltage by itself, and if it then loses its load or the grid, the voltage can climb far past its rating. Check the code in force where you are.
Selected sources
- G. Ferraris, Rotazioni elettrodinamiche prodotte per mezzo di correnti alternate, Atti della R. Accademia delle Scienze di Torino 23 (1888)
- N. Tesla, US Patent 382,279 (1888)
- AEG, German Patent DE 51,083 (1889)
- J. L. Kirtley Jr., Electric Machines, MIT OpenCourseWare 6.685
- US DOE, Premium Efficiency Motor Selection and Application Guide (2014)
- C. P. Steinmetz, Theory and Calculations of Electrical Apparatus (McGraw-Hill, 1917)
- R. R. Lawrence, Principles of Alternating Current Machinery (McGraw-Hill, 1916)
- H. M. Edvardsen and D. Winkler, Modelling the system dynamics of islanding asynchronous generators, 10th International Modelica Conference (2014)
- US DOE, direct final rule on electric motors, 88 FR 36066 (2023)
- OSHA, 29 CFR 1910.147, control of hazardous energy
- How does an induction motor make a rotating magnetic field?
- Glossary: Slip
- Glossary: Synchronous speed
Related chapters
This chapter is in Volume II: System Anatomies. Drafted and twice audited; chapter text final. Formats and prices · All chapters