Answers · from Chapter 43: The Rotating Field & the Induction Family
How does an induction motor make a rotating magnetic field?
How does an induction motor make a rotating magnetic field?
An induction motor feeds out-of-step alternating currents into coils set at angles to one another. Two coils at right angles, a quarter-cycle apart, or three coils 120 degrees apart on three-phase, add up to a field of steady strength that turns evenly. That field drags the rotor along through the currents it induces there.
Two currents, one turning field
Picture two coils fixed at right angles, one fed with a sine wave and the other with a cosine. When the first current is at its peak the second is at zero, so the field lies along the first coil. A quarter of a cycle later the roles have swapped and the field lies along the second coil. In between, the two contributions combine into a field of the same size pointing somewhere between them. The result is a field whose strength never shrinks and whose direction sweeps round at an even rate, with nothing mechanical moving at all.
Three coils spaced 120 degrees apart and fed from a three-phase supply do the same job more smoothly. MIT's Kirtley calls induction machines perhaps the most widely used electric motors.
Why the rotor follows
Currents are induced in any conductor exposed to a changing field, and they oppose the field that produced them. Put a metal rotor inside the turning field and it is dragged along, the effect Arago first reported in 1824 with a spinning copper plate and a magnet. Most motors use a squirrel cage, laminated iron carrying conducting bars in slots, with a shorting ring at each end.
Synchronous speed and slip
Adding poles slows the field. The field's speed, called synchronous speed, is 120 times the supply frequency divided by the number of poles, in revolutions per minute. A four-pole motor's field therefore turns at 1,800 rpm on 60 Hz and 1,500 rpm on 50 Hz.
The rotor can never quite catch up. At exactly synchronous speed it would see a steady field, carry no current and feel no torque. Its lag, expressed as a share of synchronous speed, is called the slip. Galileo Ferraris worked out in 1888 that the share of rotor power lost as heat equals the slip, so a motor whose slip is a few percent wastes about that share of its rotor power. The US DOE guide the chapter cites gives NEMA Design B motors a slip of 1 to 5 percent.
When there is only one phase
A single coil on household mains makes a field that pulses instead of turning. It acts like two fields spinning in opposite directions, so a motor already turning keeps going, but a stopped rotor is pulled equally both ways and just hums. Household motors therefore fake a second phase with a start winding whose current leads the main one, using finer wire or a capacitor, and the smallest fans use a copper shading ring around part of each pole.
Who thought of it
Ferraris and Nikola Tesla each produced a rotating field from out-of-step currents between 1885 and 1888. The chapter's evidence box on splitting the credit, discovery to one and invention to the other, rates that division Disputed.
Where to read more
Chapter 43 covers the history, cage and wound rotors, the induction generator and variable-frequency drives. The glossary entry on the rotating magnetic field gives the short form.
Sources
- G. Ferraris, Rotazioni elettrodinamiche prodotte per mezzo di correnti alternate, Atti della R. Accademia delle Scienze di Torino 23 (1888)
- N. Tesla, US Patent 382,279 (1888)
- J. L. Kirtley Jr., Electric Machines, MIT OpenCourseWare 6.685
- US DOE, Premium Efficiency Motor Selection and Application Guide (2014)
- C. P. Steinmetz, Theory and Calculations of Electrical Apparatus (McGraw-Hill, 1917)
Read more in Chapter 43: The Rotating Field & the Induction Family, part of Volume II: System Anatomies. All answers · Formats and prices