Volume II · Part VIII: The Bench: Units, Math & Measurement · Chapter 35

Circuits

Ohm's and Kirchhoff's laws, reactance and impedance, resonance and Q, three-phase power, and real, reactive and apparent power.

A guide to the chapter, written for this site. It describes the chapter; it is not an extract from it.

What the chapter covers

This chapter sets out the laws behind every circuit in the later volumes and carries them from direct to alternating current. It starts with Gustav Kirchhoff's 1845 paper on current in a flat plate, where his junction and loop rules first appear as a lemma, and with Georg Ohm's law of 1827 in its 1891 English translation. Series and parallel combinations and the voltage divider follow, with a worked case showing how a load pulls the output down. The AC sections define capacitive and inductive reactance with figures at 60 Hz, quote Oliver Heaviside naming impedance in 1886, and note Charles Steinmetz writing it as a complex number at Chicago in 1893. Resonance and Q are worked through the US Navy's tuned-circuit manual and a 240 µH, 100 pF tuning example, and tied to crystal sets, induction heaters and Tesla coil secondaries. A three-phase section covers wye and delta connections, the square-root-of-three factor and a Navy worked example whose printed figures run slightly low, with an evidence box on conductor savings. The chapter ends with real, reactive and apparent power, power-factor correction by capacitor, FERC Orders 827 and 904 on reactive power, and a safety box on shock currents and the charge a capacitor keeps after switch-off.

Claims the chapter rates

Each claim gets one rating on the book's scale. How the ratings work.

ClaimRatingKind
Three-phase three-wire transmission needs less conductor than single-phase two-wire for the same power, line voltage, loss and distanceProvenempirical

Key numbers

Reactance at 60 Hz
10 µF: 265 Ω; 100 mH: 37.7 Ω (computed in the chapter)
30 + j40 Ω coil on 120 V
50 Ω, 53.1°, 2.4 A, power factor 0.6 (computed in the chapter)
Wye line-to-phase voltage
√3 ≈ 1.732 (120 V phases give 208 V) (US Navy, NAVPERS 10086 (1956))
FERC Order 827 reactive-power range
0.95 leading to 0.95 lagging (FERC, 81 FR 40793 (2016))
Let-go current, 60 Hz
9.0 mA (men), 6.0 mA (women) (US Navy, NEETS Module 2 (1998))

Questions this chapter answers

What is power factor?

Power factor is the ratio of real power, in watts, to apparent power, in volt-amperes, and it equals the cosine of the phase angle between voltage and current. In the chapter's example a coil of 30 + j40 ohms on 120 V draws 288 VA but uses only 172.8 W, a power factor of 0.6.

What does Q mean in a resonant circuit?

Q is a pure number, with no units, that rates how sharp a resonance is: reactance divided by resistance, or 2π times the energy stored over the energy lost per cycle. Bandwidth equals the resonant frequency divided by Q. In a series circuit at resonance the capacitor sees the source voltage multiplied by Q.

Why is three-phase power used?

With balanced loads the combined instantaneous power of three phases stays constant, while single-phase power pulses at twice line frequency, so a three-phase motor runs with steady torque. The 1956 Navy manual Basic Electricity adds that such motors are smaller and lighter than single-phase ones of equal horsepower, and that three-phase lines need less conductor weight.

What is impedance?

Impedance is the total opposition a circuit offers to alternating current: resistance plus reactance, written as a complex number such as 30 + j40 ohms. Oliver Heaviside named it in 1886, from the verb impede. Kirchhoff's laws still hold for AC once voltages and currents are treated as phasors and impedances take the place of resistances.

Selected sources

  • G. Kirchhoff, Ueber den Durchgang eines elektrischen Stromes durch eine Ebene, insbesondere durch eine kreisförmige, Annalen der Physik und Chemie 64 (1845)
  • G. S. Ohm, The Galvanic Circuit Investigated Mathematically (1827), trans. W. Francis (1891)
  • O. Heaviside, Electromagnetic Induction and its Propagation, The Electrician 17 (1886); Electrical Papers, vol. II (1892)
  • C. P. Steinmetz, Theory and Calculation of Alternating Current Phenomena, 5th ed. (1916)
  • US Navy, Basic Electricity, NAVPERS 10086 (1956)
  • US Navy, NEETS Module 9, Introduction to Wave-Generation and Wave-Shaping Circuits, NAVEDTRA 14181 (1998)
  • US Navy, NEETS Module 2, Introduction to Alternating Current and Transformers, NAVEDTRA 14174 (1998)
  • FERC, Order No. 827, Reactive Power Requirements for Non-Synchronous Generation, 81 FR 40793 (2016)
  • FERC, Order No. 904, Compensation for Reactive Power Within the Standard Power Factor Range, 89 FR 93410 (2024)
  • 29 CFR 1910.269(w)(1)(i), OSHA capacitor rule

More on this chapter

Related chapters

This chapter is in Volume II: System Anatomies. Drafted and twice audited; chapter text final. Formats and prices · All chapters