Volume II · Part VIII: The Bench: Units, Math & Measurement · Chapter 36

Instruments

The moving-coil meter, shunts and multipliers, meter loading, the Wheatstone bridge, true RMS, electroscopes and oscilloscopes.

A guide to the chapter, written for this site. It describes the chapter; it is not an extract from it.

What the chapter covers

This chapter explains what common electrical instruments respond to and how each one disturbs the circuit it measures. It opens with Abraham Bennet's gold-leaf electrometer, described to Joseph Priestley in 1786. The moving-coil movement comes next, as the US Bureau of Standards described it in 1915 and as the Navy names it after d'Arsonval, with its radial field, springs and eddy-current damping, and the point that it always senses current. Shunts and multipliers turn that one sensor into ammeters and voltmeters, and a Navy example shows a low-resistance voltmeter misreading a loaded circuit, which leads to ohms per volt and the input resistance of digital meters. The null-method section quotes Charles Wheatstone's 1843 Bakerian Lecture and his footnote crediting Samuel Hunter Christie, with an evidence box on that priority, then extends the bridge to AC, thermistor and insulation testers. A section on AC readings separates average-responding meters from instruments that read true RMS. The electroscope returns in Oak Ridge's KFM, a leaf-type radiation meter of the 1970s, read here as an instrument design, before a closing section on cathode-ray and digital oscilloscopes. The safety box covers measurement categories, lead ratings, the amps jack and stored charge.

Claims the chapter rates

Each claim gets one rating on the book's scale. How the ratings work.

ClaimRatingKind
The four-arm null method originated with Christie (1833); Wheatstone developed it in 1843 and credited ChristieProvenempirical

Key numbers

Early voltmeter, 1915 example
0-150 V, 15 000 Ω (100 Ω/V; 10 mA full scale) (NBS Circular 20 (1915))
Moving-coil sensitivity range
1,000 to 200,000 Ω/V (US Navy, NEETS Module 3 (1998))
Loading example, true value 10 V
10 Ω meter reads 6.25 V; 10 kΩ meter reads 9.99 V (US Navy, NEETS Module 3 (1998))
Digital meter input
about 10 MΩ (volts); about 0.01 Ω (10 A jack) (Fluke, ABCs of Multimeter Safety (2014))
CAT III 1,000 V transient test
8,000 V from 2 Ω (Fluke, ABCs of Multimeter Safety (2014))

Questions this chapter answers

What is the difference between true-RMS and average-responding meters?

An average-responding meter rectifies AC, responds to the average of the result, and prints its scale in RMS through one conversion ratio valid for sine waves alone. A true-RMS meter responds to the effective value of the waveform it is given, within the crest factor and bandwidth its maker specifies. Average-responding meters misread pulses and chopped waves.

Why does a voltmeter's resistance matter?

A voltmeter becomes part of the circuit it measures. In a US Navy example, 10 V appears across a 10 Ω resistor in series with 15 Ω; a meter of 10 Ω reads 6.25 V there, while one of 10 kΩ reads 9.99 V. A meter's resistance should be high compared with the circuit, and typical digital meters present about 10 MΩ.

Who invented the Wheatstone bridge?

Samuel Hunter Christie described the four-arm null arrangement in his 1833 Bakerian Lecture. Charles Wheatstone developed it into a general resistance measurer in 1843 and, in a footnote, gave Christie credit for the first idea. The book rates the claim that the method began with Christie as Proven, on the two primary texts.

What does a meter's CAT rating mean?

A CAT rating states the size of transient a meter is designed to withstand at its place of use: CAT II covers outlet loads, CAT III fixed installations and distribution, CAT IV the point where the installation begins. In Fluke's test table, CAT III 1,000 V means an 8,000 V transient from 2 Ω. Leads need an equal or higher rating; check the code in force where you are.

Selected sources

  • A. Bennet, Description of a New Electrometer, Philosophical Transactions of the Royal Society 77 (1787)
  • Bureau of Standards, Electrical Measuring Instruments, Circular 20, 2nd ed. (1915)
  • US Navy, NEETS Module 3, Introduction to Circuit Protection, Control, and Measurement, NAVEDTRA 14175 (1998)
  • US Navy, NEETS Module 16, Introduction to Test Equipment, NAVEDTRA 14188 (1998)
  • C. Wheatstone, An Account of Several New Instruments and Processes for Determining the Constants of a Voltaic Circuit, Phil. Trans. R. Soc. 133 (1843)
  • S. H. Christie, The Bakerian Lecture, Experimental Determination of the Laws of Magneto-electric Induction, Phil. Trans. R. Soc. 123 (1833)
  • Fluke, ABCs of Multimeter Safety (2014)
  • Fluke, Why True-RMS, application note (2013)
  • C. H. Kearny, P. R. Barnes, C. V. Chester and M. W. Cortner, The KFM, A Homemade Yet Accurate and Dependable Fallout Meter, ORNL-5040 (1979)
  • IEC 61010-2-033:2023, Particular requirements for hand-held multimeters, Ed. 3.0