This chapter traces how the electrical units got their values and how a meter reading inherits its authority from them. It opens in 1965 at the National Bureau of Standards, where a group of 44 sealed cadmium cells kept in oil baths held the US volt. It then goes back to Moritz Jacobi's copied coil of 1848, Werner von Siemens's mercury-column proposal of 1860 and Wilhelm Weber's absolute units of 1846, and follows the British Association committee of 1861, its silver-platinum B.A. unit and Henry Rowland's 1878 finding that the unit was off by more than one percent. The Paris congress of 1881, the Chicago congress of 1893 and the London conference of 1908 come next, with the mercury-column ohm, the silver-voltameter ampere and the move from the Clark cell to the Weston cell. A section on standard cells compares their temperature behavior and introduces the Zener reference. The chapter then covers the 1948 change from international to absolute units, Brian Josephson's 1962 prediction and the junction arrays that held the volt from 1972, Klaus von Klitzing's 1980 quantum Hall discovery, the 1990 conventional constants and the revised SI of 20 May 2019. It closes on calibration and traceability, with an evidence box on what a NIST-traceable certificate means, and a safety box on mercury, cadmium and liquid helium.
Claims the chapter rates
Each claim gets one rating on the book's scale. How the ratings work.
| Claim | Rating | Kind |
|---|---|---|
| A "NIST-traceable" certificate does not mean NIST has checked the instrument | Proven | empirical |
Key numbers
- International ohm, Chicago 1893
- mercury column 14.4521 g, 106.3 cm, 0 °C (NBS Circular 60 (1916))
- Clark cell, 1893
- 1.434 V at 15 °C (NBS Circular 60 (1916))
- Weston normal cell, agreed from 1 January 1911
- 1.0183 international volts at 20 °C (NBS Circular 60 (1916))
- 1948 conversion, United States
- 1 int. ohm = 1.000495 Ω; 1 int. volt = 1.000330 V (Silsbee, NBS Circular 475 (1949))
- K(J-90) and R(K-90), 1990-2019
- 483 597.9 GHz/V; 25 812.807 Ω (BIPM SI Brochure (2019))
Questions this chapter answers
Where do the volt, ohm and ampere come from?
Since 20 May 2019 the volt, ohm and ampere follow from exact values given to the Planck constant h and the elementary charge e in the revised SI, with the caesium second as the time reference. Earlier they rested on objects: a British Association coil in the 1860s, then the 1893 mercury column and silver voltameter, then Clark and Weston standard cells.
What was the Weston standard cell?
The Weston cell was a reference battery that nobody drew power from: a cadmium amalgam electrode and a mercury and mercurous-sulfate electrode in saturated cadmium sulfate. Its voltage drifted far less with temperature than the Clark cell's: about minus 41 µV per °C at 20 °C, against about minus 1.2 mV per °C near 15 °C. From 1911 its agreed value was 1.0183 international volts at 20 °C.
How does a Josephson junction define the volt?
A Josephson junction, two superconductors separated by a thin barrier, develops voltage steps when microwaves drive it; each step is an integer times h/2e times the frequency. Frequency is the quantity measured best, so the junction converts it into a voltage. The National Bureau of Standards began keeping the US volt this way in July 1972.
What does NIST-traceable mean?
A NIST-traceable result is linked to a reference standard by a recorded series of calibrations, each adding its own uncertainty. It does not mean NIST has examined the instrument. NIST's policy says it certifies traceability only for results it provides itself, and that judging any other claim falls to the user. The book rates this point Proven.
Selected sources
- Bureau of Standards, Electric Units and Standards, Circular 60 (1916)
- W. J. Hamer, Standard Cells, Their Construction, Maintenance, and Characteristics, NBS Monograph 84 (1965)
- F. B. Silsbee, Establishment and Maintenance of the Electrical Units, NBS Circular 475 (1949)
- Y. Tang, N. B. Belecki and J. F. Mayo-Wells, A Practical Josephson Voltage Standard at One Volt, NIST SP 958 (2001)
- Royal Swedish Academy of Sciences, press release, Nobel Prize in Physics 1985 (16 October 1985)
- BIPM, The International System of Units (SI), 9th ed. (2019)
- S. Li, Q. Wang, W. Zhao and S. Huang, From µ0 to e, A Survey of Major Impacts for Electrical Measurements in Recent SI Revision, arXiv:2007.02473 (2020)
- JCGM 200:2012, International Vocabulary of Metrology (VIM), 3rd ed.
- NIST, NIST Policy on Metrological Traceability (updated 17 June 2024)
- D. K. Patel et al., A zero external magnetic field quantum standard of resistance at the 10^-9 level, Nature Electronics 7 (2024)
Related chapters
This chapter is in Volume II: System Anatomies. Drafted and twice audited; chapter text final. Formats and prices · All chapters