Answers · from Chapter 36: Instruments

How do true-RMS and average-responding meters differ?

How do true-RMS and average-responding meters differ?

An average-responding meter senses the average of the rectified waveform and converts it to RMS with a fixed ratio that holds only for a sine wave. A true-RMS meter responds to the effective (RMS) value of the waveform it sees, within the crest factor and bandwidth its maker states.

Why can't a meter simply read AC?

The moving-coil movement in an analog meter, which the US Navy calls the d'Arsonval movement, is too slow to follow mains frequency. Fed raw alternating current, its needle settles at the average, and over one cycle of a sine wave the average is zero. To show anything at all, the meter has to rectify the current first.

What does an average-responding meter do?

Once a rectifier sits in front of it, the movement settles at the average of the rectified wave. The maker then prints the scale in RMS by applying one fixed ratio, a ratio that is right only for a sine wave. On a clean sine wave the reading is correct. On pulses, chopped waveforms and the current drawn by switch-mode power supplies, the ratio no longer fits, and how far off the reading is depends on the shape of the wave.

What does true RMS mean?

RMS stands for root mean square, the square root of the mean of the squared waveform, also called the effective value. The US Bureau of Standards noted in 1915 that this effective value is the one "almost always desired," and warned that a moving-iron ammeter running near magnetic saturation drifts toward the average instead.

Which older instruments already read RMS?

Two early designs did. The electrodynamometer's torque followed the square of the current, while the hot-wire instrument responded to heat. Both gave the RMS value on any waveform they were fast enough to follow. Today's true-RMS meters reach the same result electronically.

Is a true-RMS meter always right?

No. The book says a true-RMS meter does the job within a stated crest factor and bandwidth, so a reading is trustworthy only inside the limits its maker specifies.

What sets where a meter may be used?

Its measurement category. CAT II covers loads plugged into outlets, CAT III fixed installations and distribution, CAT IV the point where the installation begins. Leads need the same rating or a higher one. Check the code in force where you are.

What Chapter 36 covers

Chapter 36 of The Forbidden Current explains shunts, multipliers and meter loading, the Wheatstone bridge and its history, electroscopes and oscilloscopes. It points to Chapter 5 for pulsed waveforms, form factor and power measurement.

Sources

  • Bureau of Standards, Electrical Measuring Instruments, Circular 20, 2nd ed. (1915)
  • US Navy, NEETS Module 3, Introduction to Circuit Protection, Control, and Measurement, NAVEDTRA 14175 (1998)
  • Fluke, Why True-RMS, application note (2013)
  • Fluke, Models 175, 177, 179 True RMS Multimeters Users Manual (2003)
  • Fluke, ABCs of Multimeter Safety (2014)

Read more in Chapter 36: Instruments, part of Volume II: System Anatomies. All answers · Formats and prices