Volume III · Part XIV: The Homestead Microgrid · Chapter 58
System Design
A five-step method for a stand-alone solar home, from load audit and load tiers to DC or AC bus, sizing and failure modes.
A guide to the chapter, written for this site. It describes the chapter; it is not an extract from it.
What the chapter covers
Volume III turns to whole systems here, starting with a five-step design method built on Sandia's 1995 stand-alone photovoltaic handbook, SAND87-7023. The first step is a load audit: each device's power, its daily hours and, for occasional loads, a weekly duty cycle, using the arithmetic the Department of Energy gives, with its traps named, from nameplate maximums to refrigerator cycling and standby draw. One example household, every row an assumption, comes to 3,704 Wh a day. The second step sorts loads into three tiers, the book's own framing set against Sandia's 95 and 99 percent availability levels. The third weighs a DC bus against an AC bus, comparing LBNL's 2011 model with lower field results, and notes the protection problems of low-voltage DC as Sandia's 2001 code guide, written to the 1999 NEC, describes them. The fourth step sizes the system voltage, inverter, daily battery energy, bank and array for the example, with every factor credited to its source and the result labeled as the book's arithmetic. The last builds the book's own failure-mode matrix, drawing its inverter incident figures from Sandia field records, and a safety box covers backfeed, transfer switches, carbon monoxide and battery hydrogen.
Claims the chapter rates
Each claim gets one rating on the book's scale. How the ratings work.
| Claim | Rating | Kind |
|---|---|---|
| A DC bus saves energy over an AC bus in a home | Plausible | empirical |
Key numbers
- Example household daily load
- 3,704 Wh/day AC (book's example) (Load table, the book's assumptions)
- Inverter sizing rule
- at least 125 percent of simultaneous peak (Sandia SAND87-7023 (1995))
- Example battery bank, 4 days at 50 percent depth of discharge
- 915 Ah at 48 V, about 44 kWh nominal lead-acid (book's arithmetic) (Sandia worksheet method)
- Example array current, December at 3.43 peak sun hours
- 33.3 A at 48 V, about 1.6 kW (calculated) (Sandia worksheet method, Birmingham data)
- Modeled DC-house saving
- 5 percent without storage, 14 percent with storage (modeled) (LBNL 2011)
Questions this chapter answers
How does the chapter size a stand-alone solar system?
The chapter follows Sandia's handbook: list the loads, carry the daily total back through the inverter, wire and battery factors, size the bank from days of storage, depth of discharge and a temperature correction, then size the array by current in the worst month. Every figure is the example's assumption, not a recommendation. For wiring, battery and inverter choices, check the code in force where you are.
Does running a house on a DC bus save energy?
The chapter rates the DC-bus saving Plausible: in LBNL's 2011 model a net-metered PV home saved 5 percent without storage and 14 percent with it, but the model assumed full-load efficiencies and some equipment no one sells. Test beds came in lower; in one refrigerator test the gain was 1 percent. For wiring, battery and inverter choices, check the code in force where you are.
Why does the chapter divide loads into tiers?
Loads are tiered because they matter unequally. Tier 1 is carried through any weather, Tier 2 waits for sunny surplus and Tier 3, the standby draw, is shed when storage runs short. In the example, Tier 1 alone runs about 5.2 days (the book's arithmetic) on a bank holding four days of the whole load. For wiring, battery and inverter choices, check the code in force where you are.
How large an inverter does the worked example call for?
Sandia advises at least 125 percent of the simultaneous peak, so the example's 2,765 W becomes 3,456 W and a 3,500 W unit. Motor starting is checked separately against the maker's surge rating, and light load matters too, since efficiency falls when the house idles. Check the code in force where you are.
Selected sources
- Sandia National Laboratories, Stand-Alone Photovoltaic Systems, A Handbook of Recommended Design Practices, SAND87-7023 (updated March 1995)
- US DOE Energy Saver, Estimating Appliance and Home Electronic Energy Use
- K. Garbesi, V. Vossos, A. Sanstad, G. Burch, Optimizing Energy Savings from Direct-DC in U.S. Residential Buildings, LBNL (2011)
- D. L. Gerber, R. Liou, R. Brown, Energy-Saving Opportunities of Direct-DC Loads in Buildings, LBNL (2019)
- J. Wiles, Photovoltaic Power Systems and the National Electrical Code, Suggested Practices, Sandia SAND2001-0674 (2001; describes the 1999 NEC)
- T. Gunda, R. Homan, Evaluation of Component Reliability in Photovoltaic Systems using Field Failure Statistics, Sandia SAND2020-9231 (2020)
- How do I do a load audit?
- How do I size an off-grid solar system?
- Glossary: Days of autonomy
- Glossary: Depth of discharge (DOD)
- Glossary: Peak sun hours
Related chapters
This chapter is in Volume III: Off-Grid Solutions. Drafted and twice audited; chapter text final. Formats and prices · All chapters