Answers · from Chapter 44: Transformers
How does a transformer work?
How does a transformer work?
Alternating current in one winding drives a changing magnetic flux round an iron core, and that flux passes through every turn of a second winding. Each turn gets the same induced voltage, so output voltage follows the ratio of turns, current follows the inverse ratio, and power out matches power in, less losses.
One flux, two windings
A transformer is two coils of wire wound on a shared iron core, with no electrical connection between them. C. P. Steinmetz described it in 1902 as one magnetic circuit linked with two electric circuits, a primary that takes energy in and a secondary that hands it on. Alternating current in the primary sets up an alternating flux in the core. Because the same flux threads every turn of both windings, each turn picks up an equal induced voltage.
That single fact gives the familiar rules. The ratio of output voltage to input voltage equals the ratio of secondary turns to primary turns. The ampere-turns on the two sides very nearly cancel, so current follows the inverse ratio of the voltages. Power is conserved apart from losses, and because no wire joins the windings, the transformer also isolates one circuit from the other.
What fixes the size
Chapter 44 identifies volts per turn as the number that sets a transformer's size. At a given frequency the voltage each turn can carry depends on the peak flux, which is flux density times the core's cross-section, and saturation caps the flux density. A bigger core carries more volts per turn and needs fewer turns for a given voltage. The same relation explains why a 60 Hz unit run at the same voltage on a 50 Hz supply works closer to saturation.
Losses and the core
Even with nothing connected to the secondary, a real transformer draws a small magnetizing current to set up the flux. The iron loses energy to hysteresis, reversing its magnetization every cycle, and to eddy currents circulating inside it. Laminating the core and using silicon steel keep those losses down, and they continue whenever the unit is switched on. Separate from that, the windings heat with the square of the load current.
Why it mattered in 1885
The closed-iron design shown at the 1885 Inventions Exhibition in London let two transformers share one pair of mains in parallel, each drawing almost nothing when idle. That parallel layout is still how grids distribute power.
Two safety points from the chapter
A generator connected to a building's circuits with no transfer switch can drive power backward through the utility transformer, which the US CPSC warns can electrocute line workers and neighbors served from it. Standby connections go only by way of a listed transfer switch or interlock, the chapter says. NEC Article 702 covers optional standby systems. Rules vary by place, so check the code in force where you are.
This book also does not treat microwave-oven transformers as donor parts; a separate answer explains why.
Where to read more
Chapter 44 adds leakage, inrush, three-phase banks, current transformers, oil and paper insulation, and the limits on any rewind.
Sources
- C. P. Steinmetz, Theoretical Elements of Electrical Engineering (1902)
- K. Zipernowsky, M. Déri and O. T. Bláthy, US Patent 352,105, Induction-Coil (1886)
- J. A. Fleming, The Alternate Current Transformer in Theory and Practice, vol. II (1892)
- US Navy, NEETS Module 2, Introduction to Alternating Current and Transformers (1998)
- US CPSC, Portable Generator Hazards, Safety Alert Pub. 5123 (2021)
Read more in Chapter 44: Transformers, part of Volume II: System Anatomies. All answers · Formats and prices