How does an Icyball work?

How does an Icyball work?

An Icyball is an intermittent absorption refrigerator: two sealed tanks joined by a pipe. Heating one tank drives ammonia out of water into the other tank as a liquid. Later, as the first tank cools and its water takes the ammonia back, the liquid boils and chills an insulated box.

Evidence rating: Examined, not replicated. Claim rated: One Icyball-type unit kept a 4 cu ft box at an average of 43 °F in a 16-day tropical field test. How the ratings work.

Where does the design come from?

The inventor was David Forbes Keith, a Toronto man whose US Patent 1,740,737 was applied for in 1927 and issued just before the end of 1929. Keith described an intermittent absorption system with no check valves and two vessels: a generator-absorber for the solution (water, for example) and an evaporator-condenser for the refrigerant (ammonia, for example). A 1974 US Army report calls it the Icy Ball.

What happens in each phase?

In the generating phase, the tank of water and ammonia is heated over a flame while the other tank sits in cooling water. Ammonia boils out as vapor and condenses as liquid in the cool tank.

In the refrigerating phase the roles swap. The tank of liquid ammonia goes into an insulated cabinet. As the outside tank cools, its water absorbs ammonia vapor again; the liquid ammonia boils and draws heat out of the box.

How well does it work?

For measured results the chapter has a single source, that 1974 Army report. Over 16 days of tropical field trials, while outdoor air ranged from 66 to 90 °F, the smaller 4 cu ft box held a mean of 43 °F (6.1 °C, converted), read roughly daily. The larger 8 cu ft box held a mean of 62.5 °F. Back in the laboratory, each regeneration ran 90 minutes over a camp stove, and 52 regenerations ran without a failure. The book rates the 43 °F result Examined, not replicated: one program, one unit per box size, and no heat input in watts, so no coefficient of performance can be worked out from it.

How dangerous is the ammonia?

NIOSH sets 300 ppm as the IDLH for ammonia, the level immediately dangerous to life or health, and the other figures follow. NIOSH recommends 25 ppm as a TWA for shifts up to 10 hours, and 35 ppm as a 15-minute STEL. OSHA's legal limit, the PEL, is 50 ppm averaged across 8 hours. The ILO/WHO card ICSC 0414 describes ammonia as corrosive to eyes, skin and the respiratory tract and warns of asphyxiation from throat swelling; NIOSH lists pulmonary edema among the symptoms. The gas is lighter than air, and the liquid evaporating fast can cause frostbite. NIOSH gives explosive limits of 15 to 28 percent and ICSC 15 to 33.6 percent by volume, and NIOSH says it should be treated as a flammable gas. ICSC also warns that copper, aluminium, zinc and alloys of them are attacked.

These are sealed pressure vessels. The Army units reached 140 to 150 psig during regeneration, and the report advised keeping peak pressure well under 175 psig. Nothing in the chapter is a guide to charging or building one, and the chapter says a sealed unit is replaced, not opened. Check the code in force where you are.

What Chapter 54 covers

Chapter 54, Absorption Refrigeration, explains how heat can replace a compressor, then covers the Icyball, the Platen-Munters refrigerator that uses hydrogen to avoid any pump, the Einstein-Szilard cycle and commercial lithium-bromide chillers, with a safety box on ammonia, hydrogen, pressure and codes.

Sources

  • D. F. Keith, US Patent 1,740,737, Refrigerating Device (1929)
  • N. Montanarelli, An Improved Icy Ball Refrigerator, US Army Land Warfare Laboratory TR 74-71 (1974), DTIC AD-782118
  • ILO/WHO International Chemical Safety Card ICSC 0414, Ammonia (anhydrous)
  • NIOSH Pocket Guide to Chemical Hazards, Ammonia

Read more in Chapter 54: Absorption Refrigeration, part of Volume II: System Anatomies. All answers · Formats and prices