Volume II · Part XII: Heat & Cold · Chapter 54
Absorption Refrigeration
The Icyball, the Platen-Munters gas refrigerator, the Einstein-Szilard patent, lithium-bromide chillers and what a thermal COP means.
A guide to the chapter, written for this site. It describes the chapter; it is not an extract from it.
What the chapter covers
This chapter explains refrigerators that run on heat instead of a compressor. It opens with a 1974 US Army Land Warfare Laboratory report on two tank-pair refrigerators tested at a Panama Canal Zone antenna station. It then sets out the absorption cycle as the US Department of Energy describes it, with an absorber, a solution pump and a generator in place of the compressor, the two common working pairs, the thermal coefficient of performance and its ideal ceiling. The Icyball section follows David Forbes Keith's US Patent 1,740,737 through its heating and cooling phases and reports the Army's laboratory and 16-day tropical field results. Baltzar von Platen and Carl Munters come next: US 1,609,334 added hydrogen at one total pressure so the unit needs no pump, with gravity and a thermosiphon moving the fluids, and a 2018 Imperial College prototype supplies measured figures. Albert Einstein and Leo Szilard's US 1,781,541 swaps the roles, with butane as refrigerant and ammonia as the inert gas, and a 1999 Georgia Tech study supplies its COP figures. The chapter ends with commercial lithium-bromide chillers from DOE's 2017 fact sheet, a note on why a thermal COP cannot be set beside an electric one, and a safety box on ammonia, hydrogen, pressure and codes.
Claims the chapter rates
Each claim gets one rating on the book's scale. How the ratings work.
| Claim | Rating | Kind |
|---|---|---|
| One Icyball-type unit kept a 4 cu ft box at an average of 43 °F in a 16-day tropical field test | Examined, not replicated | empirical |
| The Einstein–Szilard cycle's COP is about 0.17 | Plausible | empirical |
Key numbers
- Icyball patent
- US 1,740,737; filed 27 June 1927, granted 24 Dec. 1929 (Keith patent)
- Icyball field test, 4 cu ft box
- 43 °F (6.1 °C, converted), average of daily readings (Montanarelli, US Army LWL TR 74-71 (1974))
- Diffusion-absorption COP, one prototype
- 0.11 to 0.26, measured, cooling at 25 °C (Najjaran et al. (2018))
- Lithium-bromide chiller COP, thermal, typical full-load
- 0.70 to 0.79 single-stage; 1.35 to 1.42 two-stage (partly vendor data) (US DOE (2017), Table 2)
- Ideal COP ceiling, 90 / 30 / 5 °C
- about 1.84 (book's calculation)
Questions this chapter answers
How does an Icyball work?
An Icyball runs in two phases with two linked tanks. Heating the tank of water and dissolved ammonia drives the ammonia out, and it condenses as liquid in the second tank, held in cooling water. That cold tank then goes into an insulated box. As the first tank cools, its water takes ammonia vapor back, so the liquid ammonia boils and chills the box.
How well did the Army's Icyball test go?
Over 16 days of tropical field trials, while outdoor air ranged from 66 to 90 °F, the smaller 4 cu ft box held a mean of 43 °F (6.1 °C, converted). The book rates that result Examined, not replicated; the 8 cu ft box held 62.5 °F and fell short. In one unit's tests, each regeneration ran 90 minutes over a camp stove, with readings about once a day.
How can a gas refrigerator have no moving parts?
Baltzar von Platen and Carl Munters added hydrogen to the gas refrigerator. In US 1,609,334, granted in 1926, the entire unit shares a single total pressure, so nothing lifts the refrigerant's pressure; ammonia still boils in the evaporator because only its own partial pressure counts. Gravity and a heated thermosiphon tube move the fluids. One 2018 prototype measured a COP of 0.11 to 0.26, cooling an enclosure at 25 °C.
Did Einstein invent a refrigerator?
Einstein and Leo Szilard patented a pump-free absorption refrigerator, US 1,781,541, granted in 1930 and assigned to Electrolux Servel; the patent states the design without measured performance. It uses butane as refrigerant, ammonia as the inert gas and water as absorbent. A 1999 study abstract cites a COP of 0.17 from "recent studies", without saying whether modeled or measured, which the book rates Plausible.
How efficient are absorption chillers?
Commercial lithium-bromide chillers have typical full-load thermal COPs of 0.70 to 0.79 single-stage and 1.35 to 1.42 two-stage at 44 °F chilled water, in DOE's 2017 fact sheet, drawn partly from vendor data. That COP divides cooling by heat and leaves out pumps and fans, so it cannot be set directly beside an electric chiller's COP, which divides cooling by electricity.
Selected sources
- N. Montanarelli, An Improved Icy Ball Refrigerator, US Army Land Warfare Laboratory TR 74-71 (1974), DTIC AD-782118
- US Department of Energy, Absorption Chillers for CHP Systems, DOE/EE-1608 (2017)
- D. F. Keith, US Patent 1,740,737, Refrigerating Device (1929)
- B. C. von Platen and C. G. Munters, US Patent 1,609,334, Refrigeration (1926)
- A. Najjaran et al., Proceedings of ECOS 2018
- A. Einstein and L. Szilard, US Patent 1,781,541, Refrigeration (1930)
- S. V. Shelton, A. Delano and L. A. Schaefer, Second law study of the Einstein refrigeration cycle (1999)
- ILO/WHO International Chemical Safety Card ICSC 0414, Ammonia (anhydrous)
- NIOSH Pocket Guide to Chemical Hazards, Ammonia
- ILO/WHO International Chemical Safety Card ICSC 0001, Hydrogen (April 2014)
Related chapters