Volume II · Part XII: Heat & Cold · Chapter 56

Solar Thermal

How much sunlight reaches a surface, how collectors are rated, why idle collectors overheat, and what concentrators can do.

A guide to the chapter, written for this site. It describes the chapter; it is not an extract from it.

What the chapter covers

This chapter treats sunlight as a heat source and keeps the account in three terms: how much light arrives, how much a surface keeps and how fast it loses heat. It opens with the National Renewable Energy Laboratory's 1994 solar radiation data manual, which tabulates 1961 to 1990 averages for 239 US stations, and compares Phoenix with Seattle for fixed tilted surfaces and for two-axis tracking of the direct beam. The collector section describes unglazed mats, glazed flat plates and evacuated tubes, and explains the straight-line efficiency rating in which the intercept is optical and the slope is heat loss; NREL's illustrative lines are teaching numbers, and the chapter works its own example to show the ranking reverse as water temperature climbs. Clarence Kemp's 1891 patent for a sun-heated water tank is the primary source. A section on stagnation explains why a collector with its pump stopped grows very hot, using an NREL field evaluation. The concentrator section covers concentration ratio, tower plants with heliostat fields, a 2026 national laboratory roadmap and the eye and fire hazards of focused sunlight. The chapter ends with a safety box on stagnation, scalding, glare and fire; check the code in force where you are.

Key numbers

Phoenix, fixed surface tilted at latitude, yearly
6.5 kWh/m²/day (modeled, about ±9 percent) (Marion and Wilcox, NREL (1994))
Seattle, fixed surface tilted at latitude, yearly
3.7 kWh/m²/day (modeled, about ±9 percent) (Marion and Wilcox, NREL (1994))
Measured maximum stagnation temperature, one array
152 °C (306 °F) (Rockenbaugh et al., NREL (2016))
Desired heliostat concentration ratio
about 750 (molten salt); over 1,000 (particles) (Schell et al. (2026))
Two-axis tracking, direct beam, yearly
Phoenix 6.8; Seattle 2.9 kWh/m²/day (modeled) (Marion and Wilcox, NREL (1994))

Questions this chapter answers

How much sunlight does a solar collector receive in the US?

A collector's sunlight depends on place and aim. NREL's data manual gives a fixed south-facing surface tilted at latitude a yearly average of 6.5 kWh per square meter per day in Phoenix and 3.7 in Seattle, with an uncertainty of about 9 percent either way. In December the figures drop to 4.9 and 1.4. These are modeled station averages for 1961 to 1990.

Which is better, a flat-plate or an evacuated-tube collector?

The better collector depends on how hot the water must get. On NREL's illustrative lines, worked by the book at 800 watts per square meter with the water held 20 °C hotter than the surrounding air, the flat plate gives 60 percent and the evacuated tube 46. At 80 °C above the air the order flips, 30 against 35. NREL places evacuated tubes above about 50 °C.

Why do solar collectors overheat?

A collector is cooled by the fluid flowing through it. When the pump stops, sunlight keeps arriving and the collector heats until its losses match its gains, a state called stagnation. An NREL evaluation says this is often around 200 °C (400 °F). At one site it studied, a relief valve opened at 150 °C and vented the collector loop.

Why do concentrating solar plants need clear skies?

Mirrors and lenses can focus just the sun's direct beam, not scattered skylight. NREL's manual gives two-axis tracking a direct-beam average of 6.8 kWh per square meter per day in Phoenix but 2.9 in Seattle, and only 0.9 in a Seattle December. Concentrators trade collecting area for temperature, and tracking for that beam.

Are solar concentrators dangerous?

Solar concentrators can be dangerous: a Sandia report on glare says concentrated sunlight can cause retinal burns, and the chapter notes that a focused spot can also start fires. Idle collectors reach high temperatures and pressures, and hot water from a solar tank can scald. The chapter's safety box covers each hazard with its source.

Selected sources

  • W. Marion and S. Wilcox, Solar Radiation Data Manual for Flat-Plate and Concentrating Collectors, NREL/TP-463-5607 (1994)
  • A. Walker, Solar Water Heating, NREL/PR-7A40-56706 (2012)
  • C. M. Kemp, US Patent 451,384, Apparatus for Utilizing the Sun's Rays for Heating Water (1891)
  • C. Rockenbaugh et al., High Performance Flat Plate Solar Thermal Collector Evaluation, NREL/TP-7A40-66215 (2016)
  • S. Schell et al., Roadmap to Advance Heliostat Technologies, NLR/TP-5700-97216 (2026)
  • C. K. Ho et al., Tools to Address Glare and Avian Flux Hazards, SAND2018-10983 (2018)

Related chapters

This chapter is in Volume II: System Anatomies. Drafted and twice audited; chapter text final. Formats and prices · All chapters