Answers · from Chapter 48: Electrolysis That Actually Works

How efficient is water electrolysis?

How efficient is water electrolysis?

By DOE's status figure of 55 kWh/kg, a complete electrolysis system turns about 61 percent of its electricity into hydrogen on the LHV basis; the PEM figure is modeled. Quoted against HHV, the same plant reads about ten points higher, and a bare stack reads higher again.

By DOE's status figure of 55 kWh/kg, a complete electrolysis system turns about 61 percent of its electricity into hydrogen on the LHV basis (the PEM figure is modeled). That is DOE's status figure for both alkaline and PEM systems: 55 kWh per kilogram, set against the 33.3 kWh a kilogram of hydrogen releases when burned with its water left as vapor. Other efficiency figures in circulation usually differ from it for one of three reasons, and Chapter 48 names all three.

Why does the heating-value basis matter?

Hydrogen has two heating values. The higher one, 39.4 kWh/kg, counts the heat given back when the water vapor condenses; the lower one, about 33.3 kWh/kg, does not. The same kilowatt-hours therefore score about ten percentage points better on HHV than on LHV. NREL's 2004 survey quoted HHV; DOE's current targets quote LHV. A comparison that mixes the two is meaningless.

What is the difference between a stack and a system figure?

The stack is the pile of cells where water splits. A system adds everything else a working plant needs, and that costs energy too. DOE's status tables give 55 kWh/kg for the whole system and 51 for either stack type at 1.9 V per cell, the PEM rows modeled. In the NREL survey, the best alkaline unit drew 46.8 kWh/kg in its electrolyzer, 83 percent on HHV, and 53.4 kWh/kg for the system, 73 percent.

Does efficiency change as a plant ages?

Yes. Cell voltage creeps upward with wear, so a new stack beats its own lifetime average. DOE's PEM cost record, Program Record 24005, adds 4.2 kWh/kg of plant load to a 51 kWh/kg stack for 55.2 kWh/kg at the start of life, and models a lifetime average of 57.5 kWh/kg over a 40,000-hour stack.

How close can a cell get to the limit?

At room temperature, thermodynamics sets 1.23 V per cell, which works out to 32.7 kWh/kg. At 1.48 V, the thermoneutral voltage, the cell needs no outside heat. Working cells run at 1.7 to 2 V, the excess spent on driving the electrode reactions, pushing current through the electrolyte, and bubbles. The book's worked example at 1.9 V gives 50.5 kWh/kg, which is 78 percent on HHV. DOE's ultimate system targets are 48 kWh/kg for alkaline and 46 for PEM.

Do pulsed supplies beat steady DC?

Chapter 48 rates that claim Disputed, and part of the trouble is measurement. Multiplying average voltage by average current can understate the power a pulsed supply delivers, which can make the cell look better than it is. The Meyer claims are covered in a separate answer.

What Chapter 48 covers

Chapter 48 derives the kilowatt-hours per kilogram from Faraday's law, explains overpotential and the thermoneutral voltage, compares alkaline and PEM cells on current density, catalysts, life and cost, and sets out DOE's status figures and targets. It closes with three questions to ask of any electrolysis claim: stack or system, new or lifetime, HHV or LHV.