Volume II · Part XI: Chemical Energy · Chapter 48

Electrolysis That Actually Works

How much electricity water electrolysis takes per kilogram of hydrogen, alkaline and PEM cells, stack versus system, and pulsed claims.

A guide to the chapter, written for this site. It describes the chapter; it is not an extract from it.

What the chapter covers

Chapter 48 puts a price in kilowatt-hours on a kilogram of hydrogen made from water. Faraday's law fixes the charge at 26,590 ampere-hours per kilogram, so the energy works out to roughly 26.6 times the cell voltage. At room temperature, thermodynamics sets the floor at 1.23 V, or 32.7 kWh/kg. At 1.48 V, the thermoneutral voltage, the cell neither borrows heat from its surroundings nor sheds waste heat. Working cells sit between 1.7 and 2 V, and the chapter traces the gap to electrode overpotential, electrolyte resistance and bubbles. It explains why the heating-value basis matters: 39.4 kWh/kg on HHV against about 33.3 on LHV moves any efficiency by about ten points. Mature alkaline cells are set beside PEM cells, which run at four times the current density on iridium and platinum. DOE's status tables give 51 kWh/kg for either stack type at 1.9 V and 55 kWh/kg (61 percent LHV) for a whole system, the PEM rows modeled; NREL's 2004 survey shows the stack-to-system gap, and DOE Program Record 24005 shows new against modeled lifetime figures. The chapter ends with pulsed power, where multiplying average voltage by average current can understate the real input, and with three questions for any claimed figure: stack or system, new or lifetime, HHV or LHV.

Claims the chapter rates

Each claim gets one rating on the book's scale. How the ratings work.

ClaimRatingKind
At the same cell voltage, commercial alkaline and PEM systems use about the same electricity per kilogram of hydrogenPlausibleempirical
Pulsed power makes water electrolysis more energy-efficient than steady DCDisputedempirical

Key numbers

Thermodynamic minimum
1.23 V per cell, 32.7 kWh/kg (25 C) (Faraday's law; book's calculation)
Thermoneutral voltage
1.48 V (book's calculation (HHV basis))
Heating value of hydrogen
39.4 kWh/kg HHV; about 33.3 kWh/kg LHV (book's calculation)
Stack at 1.9 V per cell (DOE status)
51 kWh/kg, alkaline and PEM (PEM modeled) (US DOE technical targets)
Complete system (DOE status)
55 kWh/kg, 61 percent LHV (PEM modeled) (US DOE technical targets)

Questions this chapter answers

How many kilowatt-hours go into one kilogram of hydrogen?

One kilogram of hydrogen takes at least 32.7 kWh at room temperature, the floor set by 1.23 V per cell. Working cells sit near 1.7 to 2 V. At 1.9 V the book's example needs 50.5 kWh/kg at the stack, 78 percent, HHV basis. DOE's status figure for a complete system, stack plus the rest of the plant, is 55 kWh/kg, or 61 percent, LHV basis (PEM modeled).

Why do published electrolysis efficiencies disagree so much?

Three choices move published electrolysis efficiencies: a system figure adds the rest of the plant to the stack. A new cell uses less than its lifetime average, because voltage creeps up with wear. And the HHV basis reads about ten points higher than LHV for the same kilowatt-hours. DOE's PEM record gives 55.2 kWh/kg new against a modeled 57.5 over the plant's life.

Is alkaline or PEM electrolysis more efficient?

Alkaline and PEM electrolysis draw about the same electricity at equal cell voltage; at 1.9 V, DOE gives both stacks 51 kWh/kg. The chapter rates the equal-electricity claim Plausible, since the PEM row comes from modeling rather than long-sold products. Differences lie elsewhere: PEM runs near 2.0 A/cm2 against 0.5, but uses iridium and platinum; DOE lists USD 1,000 per kilowatt today against USD 500 for alkaline at high volume.

Does pulsed power make electrolysis more efficient?

The chapter rates Disputed the claim that pulsed power makes water electrolysis more energy-efficient than steady DC. Pulses alter bubble release and the charging of the electrode surface, but pulsed power is easy to mismeasure: in the book's square-wave example, average voltage times average current gives 1.7 W when the true input is 2.0 W. A 2025 paper argues from Jensen's inequality that a PEM model gains nothing from pulsing.

Selected sources

More on this chapter

Related chapters

This chapter is in Volume II: System Anatomies. Drafted and twice audited; chapter text final. Formats and prices · All chapters