Volume II · Part XI: Chemical Energy · Chapter 52
Electrochemistry at Work
Faraday's law in industry, copper refining and electrowinning, the cell voltages behind their energy, plating, and hypochlorite.
A guide to the chapter, written for this site. It describes the chapter; it is not an extract from it.
What the chapter covers
Chapter 52 takes Faraday's law out of the laboratory and into three trades. It opens with a refiner's rule of thumb that Edward Keller published and Titus Ulke reprinted in 1903: an ampere flowing for a day lays down roughly an ounce of copper. The chapter derives grams per ampere-hour for copper, nickel, zinc, silver and chlorine, and shows that energy per kilogram is cell voltage divided by current efficiency and yield. Copper refining dissolves an impure anode and plates pure metal at a fraction of a volt; a 1980 Argonne study breaks the 0.20-0.25 V into its parts and traces the gold and silver that settle as anode mud. Electrowinning usually uses a lead anode that makes oxygen instead of dissolving, which raises the cell to about 2.1 V and the energy to roughly ten times that of refining. Plating is the same cell in miniature, where current density decides the quality of the coat. The last trade is the undivided brine cell that makes sodium hypochlorite, the active ingredient of bleach, with figures from a 2006 engineering paper. The safety box covers chlorine, acids, hydrogen from the cells and the series DC supply.
Key numbers
- Copper per ampere-hour
- 1.1855 g (calculated from Faraday's law)
- Refining cell voltage
- 0.20-0.25 V (ANL/CNSV-11 (1980))
- Winning cell voltage
- about 2.1 V (ANL/CNSV-11 (1980))
- Winning energy
- 2,100-2,700 kWh per tonne of cathodes (ANL/CNSV-11 (1980))
- On-site hypochlorite
- 5.5 kWh plus 3.5 kg of salt per kg NaOCl (conv.; 0.8 percent as 8 g/L) (Casson and Bess (2006))
Questions this chapter answers
How much metal does one ampere deposit?
Faraday's law fixes the mass of metal one ampere deposits by the metal's atomic weight and charge. For copper the chapter gives 1.1855 grams per ampere-hour; Keller's figure, reprinted in 1903, was 1.18656. Over a day that comes to almost exactly one ounce, the refiners' old rule. Silver comes out at 4.025 grams per ampere-hour and zinc at 1.220.
Why does electrowinning take so much more energy than refining?
In refining the anode dissolves as the cathode grows, so the cell pays only for resistance and small electrode losses, 0.20-0.25 V in Argonne's study. In winning an inert anode, usually lead, gives off oxygen, and Argonne's table sums to 2.1 V. The book's worked example, DC at 100 percent current efficiency with refining at 0.225 V, gives 0.19 against 1.77 kWh per kilogram, a ratio of 9.3.
How is hypochlorite made from salt water?
Hypochlorite is made in an undivided cell, where the anode's chlorine reacts with the cathode's sodium hydroxide to give sodium hypochlorite, plus hydrogen. Casson and Bess describe plants running on about 3 percent brine; the chapter, taking 0.8 percent to mean 8 g/L, gets roughly 5.5 kWh and 3.5 kilograms of salt for each kilogram of product (calculated); the paper does not say whether the energy is AC or DC.
What hazards come with these cells?
NIOSH recommends a 0.5 ppm chlorine ceiling (15 minutes) and lists 10 ppm as an IDLH; ICSC 0482 warns that hypochlorite solution decomposes on contact with acids, giving off chlorine. Cells also make hydrogen, flammable at 4 to 75 percent by volume in air (ICSC 0001). Keller gave about 180 volts as the top of practice for series DC strings. Check the code in force where you are.
Selected sources
- E. Keller, in T. Ulke, Modern Electrolytic Copper Refining (Wiley, 1903)
- M. Faraday, Experimental Researches in Electricity, vol. 1 (1839)
- M. de K. Thompson, Applied Electrochemistry (Macmillan, 1911)
- L. L. Gaines, Energy and Materials Flows in the Copper Industry, ANL/CNSV-11 (Argonne National Laboratory, 1980)
- W. R. Barclay and C. H. Hainsworth, Electroplating: A Treatise on the Electro-deposition of Metals (1912)
- L. W. Casson and J. W. Bess Jr., On-Site Sodium Hypochlorite Generation, WEFTEC.06 (2006)
- NIOSH Pocket Guide, chlorine
- ILO/WHO International Chemical Safety Card ICSC 0001, Hydrogen
Related chapters