Answers · from Chapter 40: Cells & Batteries

How long does a nickel-iron (Edison) battery last?

How long does a nickel-iron (Edison) battery last?

Reported service lives run up to 25 years, and the claim that nickel-iron cells last for decades is rated Plausible. The chemistry does not use up the plates or change the electrolyte, but no published record tracks a cell's capacity across many decades, and "forever" rests on anecdote.

Evidence rating: Plausible. Claim rated: Nickel-iron batteries last for decades (popular claim: they last forever). How the ratings work.

What the maker claimed

Thomas Edison's US Patent 678,722, issued on 16 July 1901, set out a cell with a potassium hydroxide electrolyte between an iron negative plate and a positive of nickel oxide. He reasoned that finely divided iron turns into an insoluble oxide rather than dissolving in the alkali. From that he claimed an iron element that was "absolutely permanent" and an electrolyte left unchanged through the working of the battery. That is the maker's claim, made in the patent, not a measured service life.

What was measured

Part of the claim held up. In 1920 the Bureau of Standards found that neither the composition nor the specific gravity of the electrolyte changes as the cell charges and discharges. One consequence is that a hydrometer, the usual tool for reading a lead-acid cell, cannot tell you a nickel-iron cell's state of charge. The Bureau gave 1.45 to 1.52 V on open circuit and about 1.14 V as the working average at the normal rate.

A 2023 review in the journal Batteries gives service lives as long as 25 years and notes that the cells tolerate overcharge and deep discharge. That is a figure reported in a review, not a capacity record for any named cell.

What the durability costs

The weak point is the iron electrode. The Bureau noted that the cell gasses for the whole of its charge, which limits its ampere-hour efficiency: charge goes into hydrogen rather than into reducing the iron. A 2015 patent application gave about 70 percent as the charge efficiency of commercial iron electrodes. The charged iron also slowly corrodes, so a cell left standing loses charge. A self-discharge figure of 1 to 2 percent per day at 25 °C appears in the introduction of a 2020 paper, where it is attributed to work from 1991 and 1994.

Energy per kilogram is in lead-acid's range. Edison's cell held about 30 Wh/kg. In 1979 Argonne tested improved modules at 45 to 48 Wh/kg, which fell below the 58 Wh/kg goal. The 2023 review says the old problems of iron passivation and hydrogen evolution remain.

Why the rating is Plausible

The case for decades of life rests on chemistry that does not consume the plates, plus a reported 25 years. The case for "forever" rests on stories. Settling it would take a record of identified cells whose capacity and efficiency were tested repeatedly across thirty years or more of use, and the chapter found none.

Because these cells gas throughout charge, hydrogen matters: it is flammable at 4 to 75 percent by volume in air (ILO/WHO ICSC 0001). For battery installations, check the code in force where you are.

What Chapter 40 covers

Chapter 40 traces cells from Volta's pile and Planté's lead accumulator to the dry cell, sulfation, Edison's nickel-iron design and the LFP and NMC lithium cathodes, with a safety box on hydrogen, acid, lead, short circuits and lithium fire.

Sources

Read more in Chapter 40: Cells & Batteries, part of Volume II: System Anatomies. All answers · Formats and prices